Show simple item record

dc.contributor.authorGloor, Peter A.
dc.contributor.authorWeinbeer, Moritz
dc.date.accessioned2025-12-01T16:07:06Z
dc.date.available2025-12-01T16:07:06Z
dc.date.issued2025-11-15
dc.identifier.urihttps://hdl.handle.net/1721.1/164094
dc.description.abstractBackground: Quantitatively detecting whether plants exhibit measurable bioelectric differences in the presence of nearby human movement remains challenging, in part because plant signals are low-amplitude, slow, and easily confounded by environmental factors. Methods: We recorded bioelectric activity from 2978 plant samples across three species (basil, salad, tomato) using differential electrode pairs (leaf and soil electrodes) sampling at 142 Hz. Two trained performers executed three specific eurythmic gestures near experimental plants while control plants remained isolated. Random Forest and Convolutional Neural Network classifiers were applied to distinguish the control from treatment conditions using engineered features including spectral, temporal, wavelet, and frequency domain characteristics. Results: Random Forest classification achieved 62.7% accuracy (AUC = 0.67) distinguishing differences in recordings collected near a moving human from control conditions, representing a statistically significant 12.7 percentage point improvement over chance. Individual performer signatures were detectable with 68.2% accuracy, while plant species classification achieved only 44.5% accuracy, indicating minimal species-specific artifacts. Temporal analysis revealed that the plants with repeated exposure exhibited consistently less negative bioelectric amplitudes compared to single-exposure plants. Innovation: We introduce a data-driven approach that pairs standardized, short-window bioelectric recordings with machine-learning classifiers (Random Forest, CNN) to test, in an exploratory manner, whether plant signals differ between human-moving-nearby and isolation conditions. Conclusions: Plants exhibit modest but statistically detectable bioelectric differences in the presence of nearby human movement. Rather than attributing these differences to eurythmic movement itself, the present design can only demonstrate that plant recordings collected within ~1 m of a moving human differ, modestly but statistically, from recordings taken ≥3 m away. The underlying biophysical pathways and specific contributing factors (airflow, VOCs, thermal plumes, vibration, electromagnetic fields) remain unknown. These results should therefore be interpreted as exploratory correlations, not mechanistic evidence of gesture-specific plant sensing.en_US
dc.publisherMultidisciplinary Digital Publishing Instituteen_US
dc.relation.isversionofhttps://doi.org/10.3390/biomimetics10110776en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.sourceMultidisciplinary Digital Publishing Instituteen_US
dc.titleMachine Learning Distinguishes Plant Bioelectric Recordings with and Without Nearby Human Movementen_US
dc.typeArticleen_US
dc.identifier.citationGloor, P. A., & Weinbeer, M. (2025). Machine Learning Distinguishes Plant Bioelectric Recordings with and Without Nearby Human Movement. Biomimetics, 10(11), 776.en_US
dc.contributor.departmentSystem Design and Management Program.en_US
dc.relation.journalBiomimeticsen_US
dc.identifier.mitlicensePUBLISHER_CC
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2025-11-26T14:38:00Z
dspace.date.submission2025-11-26T14:38:00Z
mit.journal.volume10en_US
mit.journal.issue11en_US
mit.licensePUBLISHER_CC
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record