MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development of a Compton imager setup

Author(s)
Arya, Anuraag; Bilkhu, Harmanjeet S.; Vishwakarma, Sandeep; Belatikar, Hrishikesh; Bhalerao, Varun; Ghodgaonkar, Abhijeet; Koyande, Jayprakash G.; Marathe, Aditi; Mithun, N. P. S.; Narang, Sanjoli; Nimbalkar, Sudhanshu; Page, Pranav; Palit, Sourav; Patel, Arpit; Shetye, Amit; Tallur, Siddharth; ... Show more Show less
Download12036_2025_10110_ReferencePDF.pdf (Embargoed until: 2026-11-04, 5.307Mb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and continues onwards with a change in direction that depends on the amount of energy deposited. By using a pair of detectors to detect the point of incidence and the direction of the scattered photon, we can calculate the scattering direction and angle. The position of a source in the sky can be reconstructed using many Compton photon pairs from a source. We demonstrate this principle in the laboratory by using a pair of Cadmium Zinc Telluride (CZT) detectors sensitive in the energy range of 20–200 keV, similar to those used in AstroSat/CZT Imager (CZTI). The laboratory setup consists of two detectors placed perpendicular to each other in a lead-lined box. The detectors are read out by a custom-programmed Xilinx PYNQ-Z2 FPGA board, and data are then transferred to a personal computer (PC). There are two key updates from CZTI: the detectors are read concurrently rather than serially, and the time resolution has been improved from 20 to 7.5  μ s. We irradiated the detectors with a collimated 133 Ba source and identified Compton scattering events for the 356 keV line. We run a Compton reconstruction algorithm to correctly infer the location of the source in the detector frame, with a location-dependent angular response measure of 16 ∘ –30 ∘ . This comprises a successful technology demonstration for a Compton imaging camera in the hard X-ray regime. We present the details of our setup, the data acquisition process, and software algorithms, and showcase our results. We also quantify the limitations of this setup and discuss ways of improving the performance in future experiments.
Date issued
2025-11-04
URI
https://hdl.handle.net/1721.1/163582
Department
Massachusetts Institute of Technology. Computer Science and Artificial Intelligence Laboratory
Journal
Journal of Astrophysics and Astronomy
Publisher
Springer India
Citation
Arya, A., Bilkhu, H.S., Vishwakarma, S. et al. Development of a Compton imager setup. J Astrophys Astron 46, 84 (2025).
Version: Author's final manuscript

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.